Description
This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your IT equipment or destroy data. The SMART3000RM2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment.
Reliable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting.
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA Outlets Protect Your Connected Components
One L5-30R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split into two independently switchable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART3000RM2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
Specifications
39121011
76lb
24.5in
22.2in
9in
OVERLOAD
3.50 Minute
10 Minute
Tripp Lite
Tripp Lite
General Purpose UPS
Taiwan
19"
RoHS
Yes
3.5"
Yes
120 V AC
2 Year
3000 VA
2250 W
Tripp Lite by Eaton
SMART3000RM2U
http://www.tripplite.com
104°F (40°C)
SNMP Manageable
120 V AC
- SMART3000RM2U UPS System
- Poweralert Software With Usb, Serial & Epo Cabling
- 4 x Post Rackmount Installation Kit
- Instruction Manual
1 each
NEMA L5-30P
SmartPro
SmartPro
SMART3000RM2U UPS System
Line-interactive UPS
2U
1 x NEMA L5-30R
NEMA 5-15/20R
PowerAlert Software
5 Front Panel Leds:
- Green Power Led
- Green Voltage Correction Led
- 3 Color Battery Charge Led
- 3 Color Output Load Led
- Red Battery Warning Led
4 ms
4.50 Hour
Yes
Sine Wave
64 lb
17.5"